Brand Name : QINWEIYB

Model Number : QWBSQ-3051

Place of Origin : China

MOQ : 1Set

Price : Negotiable

Payment Terms : L/C,D/A,D/P

Supply Ability : 100PCS/Month

Delivery Time : 5-8 work days

Packaging Details : Carton

Operating Temperature : -20°C to 80°C

Application : Industrial pressure measurement

Accuracy : ±1.5%

Dial Size : 4 inches

Mounting Type : Panel Mount

Ingress Protection : IP65

Measurement Range : 0-100 psi

Material : Stainless Steel

Display Type : Analog

Response Time : Less than 1 second

Contact Now

Single Flange Level Gauge With ±0.1% FS Accuracy 150LB To 300LB

Working Principle

The single flange level gauge is a common industrial liquid level measurement instrument, also known as a single flange level transmitter. It measures the height of the liquid in the container based on pressure or differential pressure principles and outputs a standard signal (such as 4-20mA) for use by the control system.

Structural composition

  • Flange: Directly connected to the measured container, the diaphragm material can be selected from 316L, Hastelloy, tantalum, etc., to adapt to different media.
  • Capillary tube: Filled with liquid such as silicone oil to transmit pressure.
  • Transmitter body: Contains the δ chamber and amplification circuit, converting the pressure signal into a standard current signal.

Product Advantages

  1. Materials and Corrosion Resistance

    • The wetted diaphragm material is selected based on the medium: 316L stainless steel is suitable for general corrosive environments, Hastelloy C-276 is resistant to strong acids and alkalis, and tantalum can withstand strong corrosives such as aqua regia.
    • Food-grade silicone oil filling (customizable) meets FDA certification and is suitable for the dairy and beverage industries.
  2. Temperature and Pressure Adaptability

    • High-temperature compensation: Built-in temperature transmitter or capillary design reduces temperature influence. Some models support environments from -40°C to 150°C.
    • High-pressure scenarios: Flange ratings are available from 150LB (2.5MPa) to 300LB (5.0MPa), suitable for pressure vessels.
  3. Accuracy and Stability

    • Analog accuracy is typically ±0.2% FS, and intelligent models can reach ±0.1% FS, with a maximum range ratio of 100:1.
    • Long-term stability: ±0.25% FS (60 months), vibration resistance (±0.5% FS/g at 200Hz), and radio frequency interference resistance (30V/m field strength).

Typical Applications

  • Chemical and Petrochemical: Liquid level monitoring of reactors and storage tanks, suitable for high temperature, high pressure and corrosive media (such as sulfuric acid, crude oil).
  • Food and Pharmaceutical: Liquid level control of fermentation tanks and infusion bottles, meeting EHEDG and 3-A certifications, supporting CIP/SIP cleaning.
  • Water Treatment: Liquid level measurement of sewage ponds and clear water tanks, with anti-silt blockage design to ensure long-term stable operation.

Selection Comparison

Parameters Single Flange Level Gauge Dual Flange Level Gauge
Installation Complexity Simple (single flange) More complex (two flanges + capillary tube)
Cost Low High (including capillary tube and dual flanges)
Applicable Scenarios Open or low-pressure containers, with relatively clean medium Closed containers, high pressure or high viscosity medium
Accuracy High (±0.1-0.2% FS) Slightly lower due to capillary tube (±0.25% FS)
Temperature Impact Requires temperature compensation Thermal expansion of capillary tube may introduce error

Installation Points

  • Location Selection: Avoid areas with vibration and extreme temperature changes to ensure accurate measurement.
  • Flange Installation: Ensure a good seal and keep it parallel to the container wall.
  • Wiring and Debugging: Wire according to the specifications and complete zero and full-scale calibration.
  • Maintenance: Regularly check the seal and diaphragm condition to prevent medium corrosion or blockage.

Product Tags:

150LB Single Flange Level Gauge

      

300LB Single Flange Level Gauge

      

Single Flange Level Transmitter IP65

      
Buy cheap 150LB - 300LB Single Flange Level Gauge IP65 With Analog Display product

150LB - 300LB Single Flange Level Gauge IP65 With Analog Display Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi 'an Qinwei Instrument Factory (General Partnership Enterprise)
*Subject:
*Message:
Characters Remaining: (0/3000)